Pneumatic Level Control
The level control is small, effective & extremely simple to install and use. This ingenious system is operated with pneumatic components only. The level control may be installed in sumps, tanks or tubs to start (automatic with TPUK-LA or manual with TPUK-LM) and automatic stop the pump at certain liquid levels.
FULLY AUTOMATIC TPUK-LA
The level control utilizes low-pressure air passed through dip tubes to detect liquid levels. The system controls the liquid level between the dip tubes and can be configured in either ’filling’ or ’emptying’ modes.
Installation TPUK-LA
1: TPUK-LA level control
2: AODD pump
3: Blocking/needle valve
P: Air supply to level control
P1: Air supply to pump
E: ’Empty’ level tube
F: ’Full’ level tube
MANUALLY START TPUK-LM
The system controls an AODD pump that begins pumping when the system is manually started and automatically stopping when the liquid surface is detected at the dip tube. The system can be configured in either ’filling’ or ’emptying’ modes.
Installation TPUK-LM
1: TPUK-LM level control
2: AODD pump
3: Blocking/needle valve
5: Level tube
P: Air supply to level control
P1: Air supply to pump